Technical documents
Specifications
Brand
TurckMedia Monitored
Gas, Liquid
Device Type
Remote Sensor
Minimum Flow Rate
1 (Water) ccm/s, 2 (Air) ccm/s, 3 (Oil) ccm/s
Maximum Flow Rate
150 (Water) cm³/s, 30 (Air) cm³/s, 300 (Oil) cm³/s
Pipe Diameter Range
1/2 in
Connection Type
Cable
Maximum Pressure
100bar
Material
Stainless Steel
Minimum Media Temperature
-25 °C
Maximum Media Temperature
+80°C
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+70°C
Series
BIM-UNT
Current Rating
150 mA
Country of Origin
Germany
Product details
Insertion Flow Sensor (without control logic)
Requires a remote signal processor to operate, see stock no 313-2526 or 313-2532 (Available in most markets)
Pressure rating up to 60 bar static; 100 bar dynamic
Fluid temperature range: –25 to +80°C (100°C for 10 minutes maximum)
On delay time: 8s typical
Switch on time: 2s
Response time: 12s maximum
Stainless steel housing
Ingress protection to IP67
M12, four-pin plug
Flow rates: 1 to150cm3/s (water); 3 to 300cm3/s (oil); 2 to 30m3/s (air)
Stock information temporarily unavailable.
Please check again later.
₪ 2,119.32
Each (ex VAT)
₪ 2,479.60
Each (inc. VAT)
1
₪ 2,119.32
Each (ex VAT)
₪ 2,479.60
Each (inc. VAT)
1
Technical documents
Specifications
Brand
TurckMedia Monitored
Gas, Liquid
Device Type
Remote Sensor
Minimum Flow Rate
1 (Water) ccm/s, 2 (Air) ccm/s, 3 (Oil) ccm/s
Maximum Flow Rate
150 (Water) cm³/s, 30 (Air) cm³/s, 300 (Oil) cm³/s
Pipe Diameter Range
1/2 in
Connection Type
Cable
Maximum Pressure
100bar
Material
Stainless Steel
Minimum Media Temperature
-25 °C
Maximum Media Temperature
+80°C
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+70°C
Series
BIM-UNT
Current Rating
150 mA
Country of Origin
Germany
Product details
Insertion Flow Sensor (without control logic)
Requires a remote signal processor to operate, see stock no 313-2526 or 313-2532 (Available in most markets)
Pressure rating up to 60 bar static; 100 bar dynamic
Fluid temperature range: –25 to +80°C (100°C for 10 minutes maximum)
On delay time: 8s typical
Switch on time: 2s
Response time: 12s maximum
Stainless steel housing
Ingress protection to IP67
M12, four-pin plug
Flow rates: 1 to150cm3/s (water); 3 to 300cm3/s (oil); 2 to 30m3/s (air)