Specifications
Brand
MyrraSecondary Voltage Rating
7.5 → 15V ac
Primary Voltage Rating
85 → 265V ac
Power Rating
4.2W
Number of Outputs
1
Mounting Type
PCB Mount
Application
Flyback
Inductance
2.1mH
Secondary Current
900mA
Length
18mm
Width
16mm
Depth
17.5mm
Dimensions
18 x 16 x 17.5mm
Core Type
Laminated
Minimum Operating Frequency
50Hz
Construction
CEI335, CEI61558, CEI950
Number of Phases
1
Maximum Temperature
+60°C
Maximum Operating Frequency
60Hz
Country of Origin
France
Product details
Transformers for 1 → 9 W TINYSwitch II circuits
Transformers specially designed to work in conjunction with the TNY264 and TNY266 integrated circuits.
They are used to make low output switch mode power supplies with a minimum number of components.
E16 size.
Materials comply with UL94-V0.
Standards
IEC 950, IEC 61558 for reinforced insulation
Open Frame - Laminated
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.
Stock information temporarily unavailable.
Please check again later.
₪ 55.85
Each (ex VAT)
₪ 65.34
Each (inc VAT)
1
₪ 55.85
Each (ex VAT)
₪ 65.34
Each (inc VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 24 | ₪ 55.85 |
25 - 49 | ₪ 46.18 |
50 - 99 | ₪ 44.54 |
100 - 249 | ₪ 43.04 |
250+ | ₪ 41.38 |
Technical documents
Specifications
Brand
MyrraSecondary Voltage Rating
7.5 → 15V ac
Primary Voltage Rating
85 → 265V ac
Power Rating
4.2W
Number of Outputs
1
Mounting Type
PCB Mount
Application
Flyback
Inductance
2.1mH
Secondary Current
900mA
Length
18mm
Width
16mm
Depth
17.5mm
Dimensions
18 x 16 x 17.5mm
Core Type
Laminated
Minimum Operating Frequency
50Hz
Construction
CEI335, CEI61558, CEI950
Number of Phases
1
Maximum Temperature
+60°C
Maximum Operating Frequency
60Hz
Country of Origin
France
Product details
Transformers for 1 → 9 W TINYSwitch II circuits
Transformers specially designed to work in conjunction with the TNY264 and TNY266 integrated circuits.
They are used to make low output switch mode power supplies with a minimum number of components.
E16 size.
Materials comply with UL94-V0.
Standards
IEC 950, IEC 61558 for reinforced insulation
Open Frame - Laminated
PCB mounting mains transformers with a single 230Va.c. or twin 115Va.c. 50/60Hz primary winding. Independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options.