Mascot Battery Pack Charger For NiCd, NiMH Battery Pack 1 → 12 Cell with UK plug

RS Stock No.: 250-1397Brand: MascotManufacturers Part No.: 8314000120
brand-logo
View all in Battery Chargers

Technical documents

Specifications

Brand

Mascot

Battery Sizes Charged

Battery Pack

Chemistries Charged

NiCd, NiMH

Number of Cells Charged

1 → 12

Plug Type

UK

Input Voltage

230V ac

Maximum Output Power

2W

Dimensions

75 x 47 x 49mm

Weight

220g

Country of Origin

Norway

Product details

Plugtop NiCd/NiMH Packs

All suitable for charging NiCd and NiMH cells
Basic unit charges at 60mA suitable for 1 to 12 cells
The adjustable unit has an output between 50-400mA (limit to less than 250mA when charging less than 6 cells)
The fast charge unit for 2 to 10 cells charges at 570mA and the unit for 1 to 6 cells charges at 900mA and use delta V sensing to detect end of charge status and switch to a trickle charge of 14mA. End of charge safety timer fitted
LED indication
Short circuit and reverse polarity protected

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

₪ 189.04

Each (ex VAT)

₪ 221.18

Each (inc VAT)

Mascot Battery Pack Charger For NiCd, NiMH Battery Pack 1 → 12 Cell with UK plug

₪ 189.04

Each (ex VAT)

₪ 221.18

Each (inc VAT)

Mascot Battery Pack Charger For NiCd, NiMH Battery Pack 1 → 12 Cell with UK plug
Stock information temporarily unavailable.

Technical documents

Specifications

Brand

Mascot

Battery Sizes Charged

Battery Pack

Chemistries Charged

NiCd, NiMH

Number of Cells Charged

1 → 12

Plug Type

UK

Input Voltage

230V ac

Maximum Output Power

2W

Dimensions

75 x 47 x 49mm

Weight

220g

Country of Origin

Norway

Product details

Plugtop NiCd/NiMH Packs

All suitable for charging NiCd and NiMH cells
Basic unit charges at 60mA suitable for 1 to 12 cells
The adjustable unit has an output between 50-400mA (limit to less than 250mA when charging less than 6 cells)
The fast charge unit for 2 to 10 cells charges at 570mA and the unit for 1 to 6 cells charges at 900mA and use delta V sensing to detect end of charge status and switch to a trickle charge of 14mA. End of charge safety timer fitted
LED indication
Short circuit and reverse polarity protected