Finder PCB Force Guided Relay, 60 V dc Coil Voltage, 2-Pole, DPDT

RS Stock No.: 733-5110PBrand: FinderManufacturers Part No.: 50.12.9.060.5000
brand-logo
View all in Force Guided Relays

Technical documents

Specifications

Brand

Finder

Product Type

Force Guided Relay

Coil Voltage

60 V dc

Mount Type

PCB

Contact Configuration

DPDT

Number of Poles

2

Coil Resistance

5.14kΩ

Switching Current

8 A

Coil Power

700mW

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Terminal Type

Solder

Depth

12.4mm

Length

29mm

Height

25mm

Series

50

Isolation Coil To Contact

6kV

Contact Material

Gold Silver Alloy

Product details

50 Series - 50.12

Finder 50 series safety relay with forcibly guided contacts according to EN 50205 type B.

High physical separation between adjacent contacts
8mm, 6kV (1.2/50μs) isolation, coil to contact
Flux proof: RT II

Approvals

IMQ, TUV, UL recognised component for Canada and US

Stock information temporarily unavailable.

₪ 3,305.62

₪ 132.22 Each (Supplied in a Box) (ex VAT)

₪ 3,867.58

₪ 154.70 Each (Supplied in a Box) (inc. VAT)

Finder PCB Force Guided Relay, 60 V dc Coil Voltage, 2-Pole, DPDT
Select packaging type

₪ 3,305.62

₪ 132.22 Each (Supplied in a Box) (ex VAT)

₪ 3,867.58

₪ 154.70 Each (Supplied in a Box) (inc. VAT)

Finder PCB Force Guided Relay, 60 V dc Coil Voltage, 2-Pole, DPDT

Stock information temporarily unavailable.

Select packaging type

quantityUnit price
25 - 99₪ 132.22
100 - 249₪ 115.48
250 - 499₪ 98.18
500+₪ 80.31

Technical documents

Specifications

Brand

Finder

Product Type

Force Guided Relay

Coil Voltage

60 V dc

Mount Type

PCB

Contact Configuration

DPDT

Number of Poles

2

Coil Resistance

5.14kΩ

Switching Current

8 A

Coil Power

700mW

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

70°C

Terminal Type

Solder

Depth

12.4mm

Length

29mm

Height

25mm

Series

50

Isolation Coil To Contact

6kV

Contact Material

Gold Silver Alloy

Product details

50 Series - 50.12

Finder 50 series safety relay with forcibly guided contacts according to EN 50205 type B.

High physical separation between adjacent contacts
8mm, 6kV (1.2/50μs) isolation, coil to contact
Flux proof: RT II

Approvals

IMQ, TUV, UL recognised component for Canada and US