Eaton Surge Suppressor Unit 120 V ac Maximum Voltage Rating 18kA Maximum Surge Current Mains Surge Protector

RS Stock No.: 618-9597Brand: EatonManufacturers Part No.: MA15/D/1/SI/RS
brand-logo
View all in Surge Suppressor Units

Technical documents

Specifications

Brand

Eaton

Suppressor Type

Mains Surge Protector

Maximum Voltage Rating

120 V ac

Mounting Type

DIN Rail

Maximum Surge Current

18kA

Length

79mm

Depth

25mm

Height

79mm

Dimensions

90.5 x 79 x 25mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+85°C

Product details

Eaton MTL Surge & Noise Suppressor - MA15 Series

MA15 series of surge protective devices from Eaton MTL Crouse-Hinds protect electronic equipment and computer networks against "noise pollution". The MA15 units clean the effects of industrial noise and surges that may be caused by lightning strikes, switching devices and power factor correction circuits. Suitable for AC or DC application, MA15 surge protector units reduce both electromagnetic emissions and the susceptibility of the associated electrical equipment to emissions from other sources.

Features and Benefits

• 12kA surge protection and RFI filtering
• Protects panel loads up to 15 Amps in series, unlimited Amps in parallel
• Suitable for AC or DC voltage application
• LED status indication feature
• Thermal and short circuit protection
• Exceeds requirements of IEC 61000-4-5

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Stock information temporarily unavailable.

Please check again later.

Stock information temporarily unavailable.

₪ 1,223.92

Each (ex VAT)

₪ 1,431.99

Each (inc. VAT)

Eaton Surge Suppressor Unit 120 V ac Maximum Voltage Rating 18kA Maximum Surge Current Mains Surge Protector

₪ 1,223.92

Each (ex VAT)

₪ 1,431.99

Each (inc. VAT)

Eaton Surge Suppressor Unit 120 V ac Maximum Voltage Rating 18kA Maximum Surge Current Mains Surge Protector
Stock information temporarily unavailable.

Buy in bulk

quantityUnit price
1 - 9₪ 1,223.92
10 - 24₪ 1,118.76
25 - 49₪ 1,022.44
50 - 99₪ 934.26
100+₪ 853.47

Technical documents

Specifications

Brand

Eaton

Suppressor Type

Mains Surge Protector

Maximum Voltage Rating

120 V ac

Mounting Type

DIN Rail

Maximum Surge Current

18kA

Length

79mm

Depth

25mm

Height

79mm

Dimensions

90.5 x 79 x 25mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+85°C

Product details

Eaton MTL Surge & Noise Suppressor - MA15 Series

MA15 series of surge protective devices from Eaton MTL Crouse-Hinds protect electronic equipment and computer networks against "noise pollution". The MA15 units clean the effects of industrial noise and surges that may be caused by lightning strikes, switching devices and power factor correction circuits. Suitable for AC or DC application, MA15 surge protector units reduce both electromagnetic emissions and the susceptibility of the associated electrical equipment to emissions from other sources.

Features and Benefits

• 12kA surge protection and RFI filtering
• Protects panel loads up to 15 Amps in series, unlimited Amps in parallel
• Suitable for AC or DC voltage application
• LED status indication feature
• Thermal and short circuit protection
• Exceeds requirements of IEC 61000-4-5

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.