Technical documents
Specifications
Brand
ABBMonitoring Application
Phase
Electrical Phase
3
Contact Configuration
DPDT
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 30 s, 0s
Series
CM-PAS
Height
85.6mm
Length
103.7mm
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Dimensions
103.7 x 22.5 x 85.6mm
Country of Origin
Germany
Product details
CM-PAS Three-Phase Monitoring Relays
The CM-PAS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure and phase unbalance. The threshold value for phase unbalance is adjustable
Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance
Threshold value for phase unbalance adjustable as absolute value
Tripping delay can be adjusted or switched off by means of a logarithmic scale
ON-delayed tripping delay
Powered by the measuring circuit
True RMS measuring principle
2 c/o (SPDT) contacts
3 LEDs for status indication
₪ 1,899.87
₪ 1,899.87 Each (ex VAT)
₪ 2,222.85
₪ 2,222.85 Each (inc. VAT)
1
₪ 1,899.87
₪ 1,899.87 Each (ex VAT)
₪ 2,222.85
₪ 2,222.85 Each (inc. VAT)
Stock information temporarily unavailable.
1
Stock information temporarily unavailable.
| quantity | Unit price |
|---|---|
| 1 - 4 | ₪ 1,899.87 |
| 5 - 9 | ₪ 1,832.79 |
| 10 - 24 | ₪ 1,762.80 |
| 25 - 49 | ₪ 1,690.00 |
| 50+ | ₪ 1,614.18 |
Technical documents
Specifications
Brand
ABBMonitoring Application
Phase
Electrical Phase
3
Contact Configuration
DPDT
Mounting Type
DIN Rail
Phase Sensitivity
Phase Failure, Phase Imbalance, Phase Sequence
Time Delay
0.1 → 30 s, 0s
Series
CM-PAS
Height
85.6mm
Length
103.7mm
Operating Temperature Range
+60°C
Terminal Type
Screw
Minimum Operating Temperature
-25°C
Width
22.5mm
Maximum Operating Temperature
+60°C
Dimensions
103.7 x 22.5 x 85.6mm
Country of Origin
Germany
Product details
CM-PAS Three-Phase Monitoring Relays
The CM-PAS.x1 are monitoring relays for three-phase mains. They monitor the phase parameters phase sequence, phase failure and phase unbalance. The threshold value for phase unbalance is adjustable
Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance
Threshold value for phase unbalance adjustable as absolute value
Tripping delay can be adjusted or switched off by means of a logarithmic scale
ON-delayed tripping delay
Powered by the measuring circuit
True RMS measuring principle
2 c/o (SPDT) contacts
3 LEDs for status indication