Technical documents
Specifications
Brand
KEMETCapacitance
470nF
Voltage
440 V ac, 480 V ac
Mounting Type
Through Hole
Tolerance
±20%
Series
PHE844
Lead Pitch
22.5mm
Suppression Class
X1
Length
26mm
Depth
15.5mm
Height
24.5mm
Dimensions
26 x 15.5 x 24.5mm
Dielectric
Metallised Polypropylene
Lead Diameter
0.8mm
Maximum Operating Temperature
+105°C
Minimum Operating Temperature
-40°C
Country of Origin
Indonesia
Product details
PHE 844 Series
Metallised Polypropylene for use as interference suppressors in X1 and across line applications
Encapsulated in self-extinguishing material to meet the requirements of UL94V-0
Temperature Range -40°C to +105°C
Warning
X capacitors are designed for connecting directly across a mains supply but should NOT be used in positions where failure of a capacitor would expose anybody to electric shock.
Approvals
ENEC, UL, CSA
X Class - X1
₪ 639.00
₪ 12.78 Each (Supplied in a Box) (ex VAT)
₪ 747.63
₪ 14.953 Each (Supplied in a Box) (inc. VAT)
Production pack (Box)
50
₪ 639.00
₪ 12.78 Each (Supplied in a Box) (ex VAT)
₪ 747.63
₪ 14.953 Each (Supplied in a Box) (inc. VAT)
Production pack (Box)
50
Stock information temporarily unavailable.
Please check again later.
quantity | Unit price | Per Box |
---|---|---|
50 - 245 | ₪ 12.78 | ₪ 63.90 |
250 - 995 | ₪ 9.93 | ₪ 49.65 |
1000 - 2495 | ₪ 7.83 | ₪ 39.15 |
2500+ | ₪ 7.65 | ₪ 38.25 |
Technical documents
Specifications
Brand
KEMETCapacitance
470nF
Voltage
440 V ac, 480 V ac
Mounting Type
Through Hole
Tolerance
±20%
Series
PHE844
Lead Pitch
22.5mm
Suppression Class
X1
Length
26mm
Depth
15.5mm
Height
24.5mm
Dimensions
26 x 15.5 x 24.5mm
Dielectric
Metallised Polypropylene
Lead Diameter
0.8mm
Maximum Operating Temperature
+105°C
Minimum Operating Temperature
-40°C
Country of Origin
Indonesia
Product details
PHE 844 Series
Metallised Polypropylene for use as interference suppressors in X1 and across line applications
Encapsulated in self-extinguishing material to meet the requirements of UL94V-0
Temperature Range -40°C to +105°C
Warning
X capacitors are designed for connecting directly across a mains supply but should NOT be used in positions where failure of a capacitor would expose anybody to electric shock.
Approvals
ENEC, UL, CSA