Technical documents
Specifications
Brand
JumoSensor Type
PT100
Probe Length
100mm
Probe Diameter
3mm
Minimum Temperature Sensed
-50°C
Maximum Temperature Sensed
+600°C
Termination Type
Cable
Cable Length
2.5m
Probe Material
Stainless Steel
Process Connection
Probe
Number Of Wires
3
Accuracy
Class B
Response Time
4 (Water) s, 41 (Air) s
Country of Origin
Germany
Product details
Sheathed resistance thermometer in accordance with IEC 751
Working temperature from -50 °C → +600 °C
Flexible, thin-walled sheathed wire made of stainless steel; the low-ohm copper internal conducting wires are embedded in compressed, fire-resistant magnesium oxide for vibration resistance
Two or three-conductor circuit
Rapid response times
Connection lead made of silicon, 2.5 m, cable temperature range: -50 °C → +180 °C
Application-specific installation lengths
Application
Chemical plants, power plants, pipelines, in engine building, on test benches and at all measurement sites where flexibility and problem-free replacement are desirable
Stock information temporarily unavailable.
Please check again later.
₪ 1,009.11
Each (ex VAT)
₪ 1,180.66
Each (inc. VAT)
1
₪ 1,009.11
Each (ex VAT)
₪ 1,180.66
Each (inc. VAT)
1
Buy in bulk
quantity | Unit price |
---|---|
1 - 4 | ₪ 1,009.11 |
5+ | ₪ 983.03 |
Technical documents
Specifications
Brand
JumoSensor Type
PT100
Probe Length
100mm
Probe Diameter
3mm
Minimum Temperature Sensed
-50°C
Maximum Temperature Sensed
+600°C
Termination Type
Cable
Cable Length
2.5m
Probe Material
Stainless Steel
Process Connection
Probe
Number Of Wires
3
Accuracy
Class B
Response Time
4 (Water) s, 41 (Air) s
Country of Origin
Germany
Product details
Sheathed resistance thermometer in accordance with IEC 751
Working temperature from -50 °C → +600 °C
Flexible, thin-walled sheathed wire made of stainless steel; the low-ohm copper internal conducting wires are embedded in compressed, fire-resistant magnesium oxide for vibration resistance
Two or three-conductor circuit
Rapid response times
Connection lead made of silicon, 2.5 m, cable temperature range: -50 °C → +180 °C
Application-specific installation lengths
Application
Chemical plants, power plants, pipelines, in engine building, on test benches and at all measurement sites where flexibility and problem-free replacement are desirable