Technical documents
Specifications
Pressure Reading Type
Differential
Minimum Pressure Reading
20 (Rising) bar, 3.5 (Falling) bar
Maximum Pressure Reading
265 (Falling) bar, 300 (Rising) bar
Accuracy
<2 (Repeat) %
Output Type
1CO
Media Measured
Hydraulic Oil
Process Connection
G1/4
Electrical Connection
DIN43650 Male 4-Pin Connector
Supply Voltage
240 V ac, 250 V dc
Housing Material
Zinc Alloy
Mounting Type
Vertical
Maximum Operating Temperature
+70°C
IP Rating
IP65
Minimum Operating Temperature
-25°C
Country of Origin
Czech Republic
Product details
OsiSense XMLA Pressure Switches
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold.
Fixed differential
External pressure setting window available
1 NO & 1 NC snap acting contacts
Temperature range: –25 to +70 °C
Enclosure rating: IP65 with plug-in connector, IP66 with terminal connections
Operating rate: up to 120 operations / min. for diaphragm and 60 / min. for piston
Media connection: 1/4" NPT
Conduit connection: 1/2" NPT
Stock information temporarily unavailable.
Please check again later.
P.O.A.
1
P.O.A.
1
Technical documents
Specifications
Pressure Reading Type
Differential
Minimum Pressure Reading
20 (Rising) bar, 3.5 (Falling) bar
Maximum Pressure Reading
265 (Falling) bar, 300 (Rising) bar
Accuracy
<2 (Repeat) %
Output Type
1CO
Media Measured
Hydraulic Oil
Process Connection
G1/4
Electrical Connection
DIN43650 Male 4-Pin Connector
Supply Voltage
240 V ac, 250 V dc
Housing Material
Zinc Alloy
Mounting Type
Vertical
Maximum Operating Temperature
+70°C
IP Rating
IP65
Minimum Operating Temperature
-25°C
Country of Origin
Czech Republic
Product details
OsiSense XMLA Pressure Switches
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are for detection of a single threshold.
Fixed differential
External pressure setting window available
1 NO & 1 NC snap acting contacts
Temperature range: –25 to +70 °C
Enclosure rating: IP65 with plug-in connector, IP66 with terminal connections
Operating rate: up to 120 operations / min. for diaphragm and 60 / min. for piston
Media connection: 1/4" NPT
Conduit connection: 1/2" NPT